ACS32A+
ZENITHSOLAR
Availability: | |
---|---|
Quantity: | |
The equipment meets the top spectral standards:
1. A+A+A+ performance: Non-uniformity of irradiance, Spectral match and Light intensity stability all exceed the industry standards.
2. Full spectrum: The spectrum range meets the 300-1200nm range. It can realize the full spectrum test of High efficient Crystalline silicon solar cells, and the test accuracy is greatly improved.
3. Five kinds of intelligent scanning methods: conventional linear scanning method, local scanning method, hysteresis scanning method, piece wise scanning method, nonlinear scanning method, flexible operation, suitable for laboratory customer to customize test program requirements.
Measurement object: PERC, N-type, HJT, IBC, TOPcon, CIGS, ordinary crystalline silicon and other technical components
Technical parameters
Product model | ACS32A+ |
Process parameters | |
Productivity | <4S(10ms),<18S(100ms) |
Test area | 2,800mm*1,600mm |
Light source direction | side lighting |
Automation mode | Manual |
IV module parameters | |
Light source | HID(High Intensity Discharge Lamp) |
Spectrum | AM1.5 |
Light source class | A+A+A+ |
Implementation standards | IEC 60904-9:2020 |
Calibration method | Calibrate the light intensity of equipment with standard panel |
Spectral match | 0.875-1.125 (Class A +) |
Short-term instability (STI) | STI<0.2% (Class A +) |
Long-term instability (LTI) | LTI<1% (Class A +) |
Non-uniformity of irradiance | <1%(Class A +) |
Spectral range | 300-1200nm |
Irradiance time | 10-100ms |
Intensity range | 200-1200W / m² |
Repetition accuracy | <0.2% |
Xenon lamp life | 200,000W times (10ms) |
Voltage range | 0-200V (resolution 0.1mV) |
Current range | 0-30A (resolution 0.1mA) |
Testing parameters | Isc,Voc,Pmax,Vm,Im,FF,EFF,Temp,Rs,Rsh |
Software Function | 1. support 5 kinds of scanning algorithm library, one-click operation; 2. support test data saving, query, export, save automatically named in bar code, and generate to the image; 3. with automatic temperature compensation, can be customized to support multi-channel temperature monitoring; 4. support voice broadcast of test results; 5. Chinese and English interface can be freely switched; 6. support testing by parameter classification , provided alarm function for abnormal parameter ; 7. with the function of setting the permission to modify software parameters ; 8. Can be connected with MES; |
Electrical parameters | |
Test wiring | Four Wire connection |
Environment | 25℃± 5℃, 40 % RH~60 % RH |
Power | AC220V/50Hz |
Max power | 5KW |
Opertating Power | 3KW |
Equipment dimensions | Dark room: approx. 4220mm*3300mm*2160mm Capacitor box: 900mm*900mm*1800mm Electronic load box with a operating desk: 900mm*650mm*750mm Note: Light source distance from module surface 3500mm |
Picture shooted on customer's site
The equipment meets the top spectral standards:
1. A+A+A+ performance: Non-uniformity of irradiance, Spectral match and Light intensity stability all exceed the industry standards.
2. Full spectrum: The spectrum range meets the 300-1200nm range. It can realize the full spectrum test of High efficient Crystalline silicon solar cells, and the test accuracy is greatly improved.
3. Five kinds of intelligent scanning methods: conventional linear scanning method, local scanning method, hysteresis scanning method, piece wise scanning method, nonlinear scanning method, flexible operation, suitable for laboratory customer to customize test program requirements.
Measurement object: PERC, N-type, HJT, IBC, TOPcon, CIGS, ordinary crystalline silicon and other technical components
Technical parameters
Product model | ACS32A+ |
Process parameters | |
Productivity | <4S(10ms),<18S(100ms) |
Test area | 2,800mm*1,600mm |
Light source direction | side lighting |
Automation mode | Manual |
IV module parameters | |
Light source | HID(High Intensity Discharge Lamp) |
Spectrum | AM1.5 |
Light source class | A+A+A+ |
Implementation standards | IEC 60904-9:2020 |
Calibration method | Calibrate the light intensity of equipment with standard panel |
Spectral match | 0.875-1.125 (Class A +) |
Short-term instability (STI) | STI<0.2% (Class A +) |
Long-term instability (LTI) | LTI<1% (Class A +) |
Non-uniformity of irradiance | <1%(Class A +) |
Spectral range | 300-1200nm |
Irradiance time | 10-100ms |
Intensity range | 200-1200W / m² |
Repetition accuracy | <0.2% |
Xenon lamp life | 200,000W times (10ms) |
Voltage range | 0-200V (resolution 0.1mV) |
Current range | 0-30A (resolution 0.1mA) |
Testing parameters | Isc,Voc,Pmax,Vm,Im,FF,EFF,Temp,Rs,Rsh |
Software Function | 1. support 5 kinds of scanning algorithm library, one-click operation; 2. support test data saving, query, export, save automatically named in bar code, and generate to the image; 3. with automatic temperature compensation, can be customized to support multi-channel temperature monitoring; 4. support voice broadcast of test results; 5. Chinese and English interface can be freely switched; 6. support testing by parameter classification , provided alarm function for abnormal parameter ; 7. with the function of setting the permission to modify software parameters ; 8. Can be connected with MES; |
Electrical parameters | |
Test wiring | Four Wire connection |
Environment | 25℃± 5℃, 40 % RH~60 % RH |
Power | AC220V/50Hz |
Max power | 5KW |
Opertating Power | 3KW |
Equipment dimensions | Dark room: approx. 4220mm*3300mm*2160mm Capacitor box: 900mm*900mm*1800mm Electronic load box with a operating desk: 900mm*650mm*750mm Note: Light source distance from module surface 3500mm |
Picture shooted on customer's site