ZST-SMT-AAA+
ZST
9030899090
Availability: | |
---|---|
Quantity: | |
Production Description
ZST A+A+A+ Performance Validation Solar Module Xenon Lamp IV Tester
Parameter
Maximum size of tested solar cell module: 2600mm*1400mm
Light source: imported Long Arc Pulse Xenon Lamp.
Lifespan: can be lasted 150,000 times 【under the 50ms pulse condition】can be lasted 80,000 times 【under the continuously ultra-long pulse condition】
Irradiance range: 700-1200W/㎡, reach 3A+ 【under the 1000W/㎡irradiance condition】
Spectral range:300nm~1200nm 【 Grade A+】
Long term instability of irradiance: ≤1% 【 Grade A+】
Spectral matching degree: 0.875~1.125 【 Grade A+】
Non-uniformity of irradiance: ≤2% 【 Grade A】The formula: 【(Iscmax-Iscmin) / (Iscmax+Iscmin)×100%】
Testing repeatability: The same Solar Cell Module is tested continuously for 40 times, ≤0.2%
Under condition of STC, the same Solar Cell Module is tested continuously for 100 times, <0.4%.
The formula: 【(Iscmax-Iscmin) / (Iscmax+Iscmin)×100%】
Intelligent load technology:
It is standard equipped with “Isc→Voc” and “ Voc→Isc” linear scanning mode, integrated nonlinear scanning mode, double scanning mode【 magnetic hysteresis 】,
All these technologies can be switched by software.
Incident angle: diffuse reflection
Voltage range: 5V ~ 30V ~ 72V ~ 200VCurrent range: 5A ~ 15A ~ 25A ~ 40A 【selected by software】
Measurement error: Voltage ≤0.2% Current ≤0.2%
Sampling numbers: >400 【related to the sampling time】
Adopt frequency: 35K
Testing resolution: Voltage: 0.003%, Current: 0.003%
Pulse width: it can meet 10-100ms with the adjustable interval of 1ms under the irradiance of 1000W/m2.
Working mode: it automatically measures I-V curve, P-V curve and irradiance line with single flash.
Certification
Contact
Production Description
ZST A+A+A+ Performance Validation Solar Module Xenon Lamp IV Tester
Parameter
Maximum size of tested solar cell module: 2600mm*1400mm
Light source: imported Long Arc Pulse Xenon Lamp.
Lifespan: can be lasted 150,000 times 【under the 50ms pulse condition】can be lasted 80,000 times 【under the continuously ultra-long pulse condition】
Irradiance range: 700-1200W/㎡, reach 3A+ 【under the 1000W/㎡irradiance condition】
Spectral range:300nm~1200nm 【 Grade A+】
Long term instability of irradiance: ≤1% 【 Grade A+】
Spectral matching degree: 0.875~1.125 【 Grade A+】
Non-uniformity of irradiance: ≤2% 【 Grade A】The formula: 【(Iscmax-Iscmin) / (Iscmax+Iscmin)×100%】
Testing repeatability: The same Solar Cell Module is tested continuously for 40 times, ≤0.2%
Under condition of STC, the same Solar Cell Module is tested continuously for 100 times, <0.4%.
The formula: 【(Iscmax-Iscmin) / (Iscmax+Iscmin)×100%】
Intelligent load technology:
It is standard equipped with “Isc→Voc” and “ Voc→Isc” linear scanning mode, integrated nonlinear scanning mode, double scanning mode【 magnetic hysteresis 】,
All these technologies can be switched by software.
Incident angle: diffuse reflection
Voltage range: 5V ~ 30V ~ 72V ~ 200VCurrent range: 5A ~ 15A ~ 25A ~ 40A 【selected by software】
Measurement error: Voltage ≤0.2% Current ≤0.2%
Sampling numbers: >400 【related to the sampling time】
Adopt frequency: 35K
Testing resolution: Voltage: 0.003%, Current: 0.003%
Pulse width: it can meet 10-100ms with the adjustable interval of 1ms under the irradiance of 1000W/m2.
Working mode: it automatically measures I-V curve, P-V curve and irradiance line with single flash.
Certification