ZST-ZW1000
Zenithsolar
Availability: | |
---|---|
Quantity: | |
ZW1000 Series steady-state solar module tester is a LED light source steady-state solar simulator, which is used for the testing and light immersion requirements of perovskite cells. The light source of the device is direct light structure and it can simulate the real sunlight irradiation conditions.It can realize the down/up lighting installation mode according to the field environment, meeting the spectral range of 350-1100nm, and the pulse width is adjustable from 10ms to 100000ms. The device has its own test transmission unit, with production line mode, pre-processing mode, manual mode and other modes.
Test object: perovskite solar module, laminated solar module, cadmium telluride solar module, etc.
AAA standard: meet IEC60904-9 2020 standard, parameters support A+ customization
350-1100nm spectrum
Suitable for all kinds of perovskite solar modules, laminated solar modules research laboratories and production lines
Test algorithms: 5 kinds of measurement algorithms are available for customers
Supports perovskite solar cell preprocessing
Irradiance: 200~1200W/m²
Light source dynamic monitoring: The system monitors the LED status of the light source
Model | ZW1000 | |
production index | ||
Cycle | Associated with flash time | |
Max measurable area | 1200mm×600mm (Typical area) | |
Light source direction | light from downward - direct light | |
mode | Production line mode/manual mode/Preprocessing mode | |
measurement index | ||
Light source class | AAA | |
Implementation standards | IEC 60904-9 2020 | |
Calibration method | Calibrate the light intensity of equipment with standard solar panel | |
Spectral match | 0.75-1.25 (A class) | |
Irradiance instability | STI<0.5% LTI<2%(A class) | |
Non-uniformity of irradiance | <2% (A class) | |
Spectral range | 350-1100nm | |
Irradiance time | 10-100000ms | |
Intensity range | 200-1200W/m² | |
Light source type | Multispectral band LED light source | |
Light source life | >40000h | |
Constant light time | 10ms-100000ms | |
Voltage range | -10~250V(2V/10V/50V/100V/250V) | |
Current range | -5~15A(0.1A/2A/5A/10A/15A) | |
Voltage resolution Current resolution | 0.003% 0.003% | |
Voltage accuracy Current accuracy | 0.2% 0.2% | |
Effective data point | ≥1000(10ms) | |
Measuring parameter | Isc,Voc,Pmax,Vm,Im,FF,EFF,Temp,Rs,Rsh | |
Electrical index | ||
Measured power | 1000W(Max) | |
Test wiring | four-wire system | |
Cooling water | 50L/min,3-4bar | |
Air source | 0.6-0.8Mpa | |
Work environment | Temperature: 25℃±10℃; Relative humidity: ≤85% | |
Power | AC380V/50Hz/20A Three-phase five-wire system,the ground resistance<1Ω |
ZW1000 Series steady-state solar module tester is a LED light source steady-state solar simulator, which is used for the testing and light immersion requirements of perovskite cells. The light source of the device is direct light structure and it can simulate the real sunlight irradiation conditions.It can realize the down/up lighting installation mode according to the field environment, meeting the spectral range of 350-1100nm, and the pulse width is adjustable from 10ms to 100000ms. The device has its own test transmission unit, with production line mode, pre-processing mode, manual mode and other modes.
Test object: perovskite solar module, laminated solar module, cadmium telluride solar module, etc.
AAA standard: meet IEC60904-9 2020 standard, parameters support A+ customization
350-1100nm spectrum
Suitable for all kinds of perovskite solar modules, laminated solar modules research laboratories and production lines
Test algorithms: 5 kinds of measurement algorithms are available for customers
Supports perovskite solar cell preprocessing
Irradiance: 200~1200W/m²
Light source dynamic monitoring: The system monitors the LED status of the light source
Model | ZW1000 | |
production index | ||
Cycle | Associated with flash time | |
Max measurable area | 1200mm×600mm (Typical area) | |
Light source direction | light from downward - direct light | |
mode | Production line mode/manual mode/Preprocessing mode | |
measurement index | ||
Light source class | AAA | |
Implementation standards | IEC 60904-9 2020 | |
Calibration method | Calibrate the light intensity of equipment with standard solar panel | |
Spectral match | 0.75-1.25 (A class) | |
Irradiance instability | STI<0.5% LTI<2%(A class) | |
Non-uniformity of irradiance | <2% (A class) | |
Spectral range | 350-1100nm | |
Irradiance time | 10-100000ms | |
Intensity range | 200-1200W/m² | |
Light source type | Multispectral band LED light source | |
Light source life | >40000h | |
Constant light time | 10ms-100000ms | |
Voltage range | -10~250V(2V/10V/50V/100V/250V) | |
Current range | -5~15A(0.1A/2A/5A/10A/15A) | |
Voltage resolution Current resolution | 0.003% 0.003% | |
Voltage accuracy Current accuracy | 0.2% 0.2% | |
Effective data point | ≥1000(10ms) | |
Measuring parameter | Isc,Voc,Pmax,Vm,Im,FF,EFF,Temp,Rs,Rsh | |
Electrical index | ||
Measured power | 1000W(Max) | |
Test wiring | four-wire system | |
Cooling water | 50L/min,3-4bar | |
Air source | 0.6-0.8Mpa | |
Work environment | Temperature: 25℃±10℃; Relative humidity: ≤85% | |
Power | AC380V/50Hz/20A Three-phase five-wire system,the ground resistance<1Ω |